- SS7 protocol simulator/protocol tester
- SS7 over E1/T1/J1
- SS7 over IP (SCTP/M3UA)
- Notebook and desktop solutions
- SS7 Conformance Test Suite Framework included
- Running with Windows 2000 and Windows XP
- Expandable to support SS7 protocol analysis, and BICC, V5 and ISDN PRA protocol simulation and analysis by adding software modules

-
SS7 simulation over E1/T1/J1 and IP (M3UA/SCTP)
- Multiple E1/T1/J1 line interfaces supported
- Auto detect layer 1 & layer 2 settings
- MTP2 protocol machine
- Multiple MTP links
- Automatic handling of MTP2 and SMH
- SCTP and M3UA protocol machines
- Simulating a SGP handling several ASPs
- Simulating one or more ASPs
- Multiple routing keys
- Scriptable handling of M3UA endpoints
- Scriptable handling of SCTP associations
- Multiple SCTP associations
- Multiple SCTP streams
- Multihoming
- CRC-32c and Adler-32 checksum support
- Script-based testing
- Script and Parameter Builder
- Automatic answering incoming messages
- Conformance Test Suite Framework included
- Voice input/output through PC microphone/speakers
- DTMF generator/detector
- ITU, ANSI, TTC and national protocol standards supported
- Application Programming Interface (API)

- SSP and STP simulation: The STINGA SS7 Simulator can be used to simulate against SSPs and STPs.
- SGP and ASP simulation: The STINGA SS7 Simulator can be used to simulate a SGP or one or more APSs.
- Error Tracking: Comprehensive protocol decoding of all user parts and
protocol layers makes it possible to track and search for protocol
irregularities. Recorded irregular messages may be regenerated with
the protocol simulator. This is a very convenient way of reproducing errors
in the network.
- Interconnect Testing: A comprehensive conformance test suite frqmework based on the ITU Q.78x series test specifications is included with the STINGA SS7 Simulator.
-
Regression Testing: Building script libraries of scripts enables the user to do
automated and fast regression testing.
- Mobile Testing: With support for CAMEL, INAP, MAP and SMS, the STINGA SS7 Simulator may be used for mobile testing against BSCs and MSC/VCRs.
-
IN Testing: Using the simulator the user may build IN messages to perform IN script testing.
- Call Generation: The STINGA SS7 Simulator is able to generate about 200 calls per second (dependent of the size of the messages to be sent) for load testing.
- Simultaneous Protocol Simulation and Analysis: Possible to simulate on one side of a test object (i.e. a switch) and monitor on the "other" side.
- Remote Control: The STINGA SS7 instrument can be controlled remotely over LAN/WAN (like a dial-up connection). E.g. it is possible to control two separate remote test instruments from one local computer using two B-channels on one ISDN Basic Access.

The SS7 protocol simulator is designed to be used by both skilled and unskilled users: From easy and quick testing by point-and-click to more advanced and flexible script-based testing.
Simulator Processes
The SS7 Simulator product has two simulator processes that can simulate the same or different user parts simultaneously. These simulators can be connected to the same timeslot on the same E1/T1, and to timeslots on different E1/T1s. E.g. one of the simulators can simulate ISUP on one E1, and the other simulator can simulate SCCP on another E1 simultaneously. Both simulator
processes can be configured as
Terminal (slave timing) and Net
(master timing).
Automatic MTP2 and SMH
Layer 2 mechanisms are handled automatically. Point codes can be specified manually, or they are automatically picked up from the first incoming message.
SLTM/SLTA handshaking is also automatically handled.
Call & Release Call guides
Call setup and termination are easily done from dialogs which guides the user through the generation of outgoing calls and termination of calls. These guides are combined with a Parameter Builder.
Protocols and User Parts
Simulation of different protocols and user parts like MTP, ISUP, TUP/IUP, SCCP, TCAP, MAP, SMS, IN, MWI and CCBS simulation are supported.
Audio Monitoring and DTMF Generator/Detector
The DTMF Generator makes it possible to send single DTMF tones and to specify a series of digits to be sent as DTMF tones. When DTMF tones are sent/received, message are printed in the one-line decoding window. Received DTMF tones and audio is played in the PC-speakers for the PCMCIA solutions, and in the connected handset for the PCI solutions.
Parameter Builder
A parameter builder simplifies the parameter building. Different dialogs are reflecting the specification of the different parameters required to make outgoing calls. For advanced or out of spec modifications, the user is able to make modifications on hex/bit level.
Call Generation
In call generation mode, one simulator process is only sending messages while the other simulator process is only responding to incoming messages. The Call Generator is able to send about 200 calls per second (dependent of the size of the messages to be sent). Sending with “shared flags” is also supported.
Script Language
A powerful and flexible script language makes it possible to set up a required/desired (protocol/terminal) state, both normal and error states. There are no restrictions on neither format nor content of the protocols transmitted/received. Arbitrary manipulation (down to bit level) of messages, parameters and message sequence on the different protocols are allowed. The test scripts may be started manually or they can be automatically triggered by incoming messages.
Remote Control
The simulator application is constructed to be remotely controlled over a IP connection (like a dial-up connection). The graphical user interface is installed on a local computer, while the simulator “agent” is running on a remote computer connected to the test object through the PIST hardware.
Conformance Test Suite Framework
Repeated use of the simulator to perform similar tests is significantly alleviated if a library structure of test scripts is built. Examples of situations where this is recommended are interconnect testing between network operators as well as functional testing, regression testing and conformance testing of terminal
equipment and/or network elements. A library of test scripts is available as a framework for the user for building a dedicated test environment. The library is based on the ITU-T Q.782 (MTP Level 3), Q.784 (Basic Call), Q.785 (Supplementary Services) and Q.788 test specifications.

The STINGA SS7 Simulator product is supporting the following protocols:
- SS7 over E1/T1/J1:
- E1/T1/J1 alarm signals and link status:
- Loss of Frame Alignment
- Loss of Signalling Multiframe Alignment
- Loss of CRC Multiframe Alignment (red alarm)
- Remote Alarm and Remote Multiframe Alarm (yellow alarm)
- Alarm Indication Signal (AIS) (yellow alarm)
- MTP (ITU, ANSI, Japan/TTC) - Message Transfer Part
- SNM - Signalling Network Management
- SMH - Signalling Message Handling
- SS7 over IP:
- ISUP (ITU, ANSI, UK, Japan/TTC) - ISDN User Part
- BICC - Bearer Independent Call Control
- TUP - Telephone User Part
- IUP (British Telecom TUP)
- SSUTR2 (French TUP)
- SCCP (ITU, ANSI, TTC) - Signalling Connection Control Part
- TCAP (ITU, ANSI) - Transaction Capabilities Application Part
- INAP - Intelligent Network Application Part:
- Core INAP
- INAP CS1
- INAP CS2
- Ericsson Core INAP
- Alcatel Core INAP
- Siemens INAP: SINAP5 and SINAP7
- Ericsson INAP CS1+
- Alcatel INAP CS1+
- British Telecom INAP CS1+
- Ericsson Light Weight INAP
- MAP - Mobile Application Part
- SMS - Short Message Service
- CAP - CAMEL Application Part
- IS-41/ANSI-41
- GSM and CDMA A-interface:
- BSSAP - Base Station System (BSS) Application Part
- BSSMAP - BSS Management Application Part
- DTAP - Direct Transfer Application Part
- MM - Mobility Management
- RR - Radio Resource
- CC - Call Control
- GPRS Mobility Messages
- GPRS Session Management Messages
- Supplementary Services
Support for new protocols and protocol versions are added continuously, so please contact Utel Systems if you don't find the protocols of interest.
Other protocols and national protocol variants are also implemented on customer requests.

|
Feature |
Benefit |
|
PCMCIA based instrument |
Highly portable and cost-efficient technology. |
|
All-in-one concept |
Many applications - one notebook. |
|
Similar user interface for all applications |
Easy-to-use applications and reduced training costs, easy to move between monitor
and simulator applications. |
|
Windows platform |
Cost-efficient IT service, fast access to replacement units and familiar user interface. |
|
Open script format |
Content and order of any message or parameter can be changed. The
simulator can therefore simulate any regular or irregular/incorrect
protocol implementation and be adapted to new protocol elements. |
|
Conformance Test Suite Framework |
Comprehensive conformance test suite for ISUP interconnect testing according to ITU-T Q.782, Q.784, Q.785 and Q.788 test specifications. |
|
Remote control |
Efficient use of central expert competence/know-how and reduced travelling and
training costs. |
|
Same decoding format for monitor and simulator |
Time efficient testing. |

About this product:
Related products:
|