Board Specification |
|
Host Bus Interface |
- PCI Rev. 2.1 electrical interface
- Memory mapped interface
|
Network Interfaces |
- 8 E1/T1/J1 (software switchable)
|
Line Termination |
|
H.100 Interface |
- 32 x 2, 4, or 8 Mbit/s board-to-board highways
- 256 simplex channels switchable between adapters
- 1024 channels switchable locally
- Backwards compatible with MVIP and SC-Bus
|
DSP Resources (with optional ASM daughterboard) |
- PIST-55x4-ASM: 4 x TI TMS320VC5510 (400 MIPS) with 16MB SDRAM each
- PIST-5x4-ASM: 4 x TI TMS320C548/549 (80 MIPS) with 512KB SDRAM
|
HDLC Resources |
- Support for 3 HDLC channels per access port
- ASM modules offer additional HDLC channels with support for super- and sub-channels
|
E1/T1/J1 Frame Formats |
- Doubleframe, CRC Multiframe (E1 mode)
- F4, SF (or D4), ESF (or F24), SLC96 (T1/J1 mode)
|
E1/T1/J1 Line Codes |
- HDB3, B8ZS, AMI, AMI with ZCS
|
E1/T1/J1 Signalling Types |
- Channel associated (robbed bit)
- Common channel
|
Clocking sources |
- Onboard oscillator (high-stability oven-controlled oscillator option available)
- Incoming E1/T1/J1 span
- H.100 clock
- External clock
|
Connector |
- 50-pin Centronix, 3-foot cable to harmonica with RJ45/RJ45C connectors for E1/T1/J1, and RJ11 connectors for handsets
|
Testing Features |
- Full access to F, Y, Si, and Sa bits in E1 mode
- Full access to FS/DL-bits in T1 mode (including support for the DL-channel protocol according to T1.403-1989 ANSI or to AT&T TR54016 specification), and programmable line build-out in T1/J1mode
- Transparent mode and programmable transmit pulse shape and input threshold
- Alarm insertion and detection
- Loop codes, channel loopback and PRBS
|
Phone Features |
- 4 analog interfaces (codecs) for handset connections
|
Power Requirements/Environmental Data |
- Power consumption: 7.4W
- Temperature: operating, 0 C to +50 C; non-operating, -40 C to +60 C
- Humidity: operating, 5% to 80% RH (%relative humidity) at up to +30 C, and 5% to 30% RH above +30 C up to +50 C non-condensing; non-operating, 5% to 80% RH at up to +30 C, and 5% to 30% RH above +30 C up to +50 C non-condensing
- Altitude: operating, up to 4,600 meters (15,333 feet); non-operating, up to 12,192 meters (50,000 feet)
|
Device Drivers |
- Windows NT 4.0
- Windows 2000
- Windows XP
- Linux
|
API |
- Device Driver SDK
- DSP SDK
|