| Board Specification | |
| Host Bus Interface | - PCMCIA electrical interface
- I/O mapped, SW configurable IRQ
|
| Network Interfaces | - 2 T1, E1 or J1 (software configurable)
|
| Line Termination | - 75 Ohm and 100/120 Ohm or high impedance
|
| DSP | - 2x TI TMS320VC5416 with 160 MIPS processing power each
|
| DSP Programming Interface | - Software development kit in ANSI C and C++
- Open interface with standard third-party tools
|
| DSP Applications | - DTMF, MF, FSK, and generic tone (e.g., dial-tone and call progress tone) generation and detection
- Speech compression, encoding and decoding
- HDLC processing
- G.726 ADPCM, G.168 line echo canceller, VAD, AGC, CNG, CPTD etc. (as part of the CST DSP ROM)
|
| T1/E1/J1 Frame Formats | - Doubleframe, CRC Multiframe (E1 mode)
- F4, SF (or D4), ESF (or F24), SLC96 (T1/J1 mode)
|
| T1/E1/J1 Line Codes | - HDB3, B8ZS, AMI, AMI with ZCS
|
| T1/E1/J1 Signaling Types | - Channel associated (robbed bit)
- Common channel
|
| Clocking Sources | - Onboard oscillator
- Incoming T1/E1/J1 span
|
| Connector | - RJ45/RJ48C in dongle (two dongles per board)
|
| Testing Features | - Full access to F, Y, Si, and Sa bits in E1 mode
- Full access to FS/DL-bits in T1 mode (including support for the DL-channel protocol according to T1.403-1989 ANSI or to AT&T TR54016 specification), and programmable line build-out in T1/J1 mode
- Transparent mode and programmable transmit pulse shape and input threshold
- Alarm insertion and detection
- Loop codes, channel loopback and PRBS
|
| EMC and Safety Testing / Certification | - FCC Part 15 (CFR47, Part 15, Subpart B)
- CE EMC (EN61326-1 Class B Equipment, AS/NZS 2064 Class B Limits)
- Safety EN60950 and UL60950 (dongle only)
|
| Power Requirements / Environmental Data | - Power consumption: 3.0W
- Temperature: operating, 0° C to +50° C; non-operating, -40° C to +60° C
- Humidity: operating, 5% to 80% RH (%relative humidity) at up to +30° C, and 5% to 30% RH above +30° C up to +50° C non-condensing; non-operating, 5% to 80% RH at up to +30° C, and 5% to 30% RH above +30° C up to +50° C non-condensing
- Altitude: operating, up to 4,600 meters (15,333 feet); non-operating, up to 12,192 meters (50,000 feet)
|